NEW QUESTION 33
Welding procedures qualified by may be used, subject to the specific approval of the inspector

  • A. the employer
  • B. the use of AWS pre qualified, D1.1 type procedures
  • C. others
  • D. the use of API 1104 qualified procedures

Answer: C

 

NEW QUESTION 34
Impact testing of each form of material for any specification shall be done using procedures and apparatus in accordance with

  • A. AWS D 1.5
  • B. ASME Section V
  • C. API 570
  • D. ASTM A 370

Answer: D

 

NEW QUESTION 35
During a welder qualification test on 3/8" plate in the horizontal position, how many guided bends are required?

  • A. 1 face and 1 root bends
  • B. 6 side bends
  • C. 2 nick breaks
  • D. 4 tensile specimens

Answer: A

 

NEW QUESTION 36
What is the pressure design thickness of NPS10A516 Gr.65 Type 22 pipe that operateat 1200psig/750°F

  • A. 0.928"
  • B. Not enough in formation given
  • C. 0.46"
  • D. 0.432"

Answer: C

 

NEW QUESTION 37
Which of the following applies to socket welds in piping systems?

  • A. Should be avoided
  • B. Should be welded using SAW only
  • C. Should be used in all welded piping
  • D. Should be avoided where crevice corrosion may occur

Answer: D

 

NEW QUESTION 38
A leak test is an alternative to inspection of buried piping.
What is the minimum liquid pressure to adequately conduct this test?

  • A. 1 1/4 times the MAWP
  • B. 1 1/2 times the MAWP
  • C. 10% greater than MAWP
  • D. Actual MAWP

Answer: C

 

NEW QUESTION 39
An individual who holds an engineering degree is automatically qualified as.

  • A. a NDE Level II or III in any technique
  • B. a piping Inspector
  • C. None of the above
  • D. an authorized piping inspector

Answer: C

 

NEW QUESTION 40
The radiograph of a Normal Fluid service piping weld revealed a crack.
What is the acceptable crack length if the pipe wall was 0.375?

  • A. 3/16"
  • B. None
  • C. T/3
  • D. Cracks will not show on radiographs

Answer: B

 

NEW QUESTION 41
In a piping circuit, which of the following does not routinely have thickness measurements taken?

  • A. Valves
  • B. Dead legs
  • C. Straight Run Pipe
  • D. Fittings

Answer: A

 

NEW QUESTION 42
What does the acronym MAWP refer to?

  • A. Minimum internal pressure permitted in the piping system
  • B. Maximum external pressure permitted in the piping system
  • C. Maximum internal pressure permitted in the piping system
  • D. Maximum external stress permitted in the piping system

Answer: C

 

NEW QUESTION 43
A piping system has a corrosion rate of 0.074 inches per year, the actual wall thickness is 0.370 inches and the minimum required thickness is 0.1 inch.
What is the remaining life?

  • A. 3.6 months
  • B. 36.48 years
  • C. 3.6 years
  • D. 364.8 years

Answer: C

 

NEW QUESTION 44
Given the above information, what is the short term corrosion rate of the above piping system?

  • A. Not enough information given
  • B. 0.005 inches per year
  • C. 550 Inches per year
  • D. 0.055 inches per year

Answer: D

 

NEW QUESTION 45
all suspect areas and areas of damaged insulation should be examined?

  • A. 100%
  • B. 10%
  • C. 33%
  • D. 50%

Answer: B

 

NEW QUESTION 46
What is the definition of normalizing?

  • A. Process where a ferrous metal is heated to a suitable temperature above the transformation range and is subsequently cooled in still air at room temperature.
  • B. Heating an alloy to a suitable temperature, holding that temperature long enough to allow constituents to enter into solid solution and then cooling ~ rapidly enough to hold the constituents.
  • C. Heating to and holding at a suitable temperature and then cooling at a suitable rate to reduce hardness, improve machinability, facilitate cold working, etc.
  • D. Rapid cooling of a heated metal

Answer: A

 

NEW QUESTION 47
The repair organization shall use welders and welding operators qualified in accordance with the code to which the piping was built or alternatively_____.

  • A. ASME Section V
  • B. AWS D 1.1
  • C. API 1104
  • D. ASME B 31.3

Answer: D

 

NEW QUESTION 48
The weld ripples of reinforcement of butt-welded joints shall be before radiography.

  • A. ground flush, with grinding direction perpendicular to the weld
  • B. removed if irregularities mask discontinuities
  • C. ground flush, with grinding direction parallel to the weld
  • D. removed

Answer: B

 

NEW QUESTION 49
Piping systems that are not located in high activity areas and do not significantly vaporize are designated as______.

  • A. Class 3
  • B. Class 1
  • C. Owner/user designated system
  • D. Class 2

Answer: A

 

NEW QUESTION 50
When testing cast iron pipe which of the following methods should not be used?

  • A. Radiographic test
  • B. Leak test
  • C. Hammer test
  • D. Ultrasonic test

Answer: C

 

NEW QUESTION 51
In evaluating blisters and laminations in piping, assessments should be performed in accordance with_____.

  • A. API 598, Section 1
  • B. API RP 579, Section 7
  • C. ASME 816.5
  • D. API RP 2207, Section 2

Answer: B

 

NEW QUESTION 52
In the AWS D 5.1, what is the designation for cellulose DCEP electrode?

  • A. E 7018
  • B. E 6010
  • C. E 7016
  • D. E 6011

Answer: B

 

NEW QUESTION 53
On a class 1500 NPS 4 blind flange, what is the minimum thickness permitted?

  • A. 2.12"
  • B. 1.12"
  • C. 1.88"
  • D. 2.88"

Answer: A

 

NEW QUESTION 54
With respect to Category 'D' service, what is the maximum allowable undercut for a branch connection?

  • A. £ 1 mm
  • B. Both B and C
  • C. Zero (no evident imperfections)
  • D. £ 1/32"

Answer: B

 

NEW QUESTION 55
The base metal is P No.1, the weld metal is A No.1, and the wall thickness is 7/8".
What is the holding time at 1100- 1200?F for heat treatment

  • A. Procedure is not required for this thickness
  • B. 1 hour
  • C. 3 hours
  • D. 2 hours

Answer: B

 

NEW QUESTION 56
The potential for personnel exposure is deemed to be significant in which fluid service?

  • A. Category B fluid service
  • B. Normal fluid service
  • C. High pressure fluid service
  • D. Category M fluid service

Answer: D

 